20 questions across every section. Each section comes back against the 70 percent line, the way the exam scores each section on its own.

What it measures

20 scored questions across the four exam sections, weighted like the exam. Each one is marked as you answer it, with the explanation under it.

Free, no account, and you can stop whenever you like.

What comes back

Each section's score against the 70 percent pass mark. 30 TAC 30.20(b) sets that mark and TCEQ applies it to each section on its own, so it is the exam's own line and not ours.

See the readout's shape, built from an example sitting, before you sit anything.

Why every section is scored on its own

The exam has four sections, sat together, and each one has to reach 70 percent on its own. A strong score on one does not carry a weak one on another, so this readout puts each section against its own line instead of adding them together. With a few questions a section it is a rough read: use it to see which section to start on.

What you may take in

A pen or pencil, scratch paper from the proctor and a non-programmable calculator. TCEQ does not allow books, notes, phones or other electronic devices in the examination room. This diagnostic is untimed and you can look things up, so do not read the score as a prediction. On the day, with no notes and a clock running, expect lower.

Before you pay for another sitting

The application fee is $111, paid to TCEQ with the application; it is the fee for a three-year license and is nonrefundable. The computer-based testing center charges its own seat fee on top, and each center sets its own. A failed section cannot be sat again until its result is in, and the application expires after 365 days or on failing the same section four times. The diagnostic is free, and its readout tells you how far a section is from the line.

Every question in this diagnostic

  1. Where the maker gives no depth figure, irrigation pipe needs a minimum cover of:

    • A 2 in Two inches is the reduced cover allowed only where a utility, a structure or roots make the 6 inch cover impractical.
    • B 6 in Correct
    • C 12 in The state minimum is 6 inches of select backfill; no 12 inch cover is set for irrigation pipe.
    • D 18 in The state minimum is 6 inches of select backfill; no 18 inch cover is set for irrigation pipe.

    Where the manufacturer publishes no depth coverage figure, piping must have at least 6 inches of select backfill between the top of the topmost pipe and the natural grade (30 TAC 344.62(l)(1)). The 2 inch figure applies only where a utility, a structure or roots make the 6 inch cover impractical (30 TAC 344.62(l)(2)).

    30 TAC 344.62(l)(1) and (l)(2)

  2. On a new system, the isolation valve is installed:

    • A Between the meter and the backflow device Correct
    • B Downstream of the master valve The master valve sits downstream of the backflow assembly; the isolation valve belongs upstream of the assembly, after the meter.
    • C At each zone valve Zone valves control single zones; the rule places the isolation valve between the meter and the backflow assembly.
    • D Upstream of the water meter The rule puts the isolation valve after the meter, between it and the backflow assembly, not ahead of the meter.

    Every new irrigation system must include an isolation valve between the water meter and the backflow prevention assembly, so the valve sits after the meter and ahead of the assembly (30 TAC 344.62(k)).

    30 TAC 344.62(k)

  3. Which valve turns a single zone on and off?

    • A The master valve A master valve controls the flow of water to the whole mainline, not one zone.
    • B The isolation valve An isolation valve shuts off the supply between the meter and the backflow assembly; it does not run a zone.
    • C The zone valve Correct
    • D The quick coupler valve A quick coupler valve gives hose or key access to water; it does not switch a zone on and off.

    A zone valve is the automatic valve that controls only a single zone of the system. A master valve controls flow to the whole mainline instead (30 TAC 344.1(47)).

    30 TAC 344.1(47)

  4. According to TCEQ, where does a master valve go when one is installed on a new system?

    • A Upstream of the backflow device The rule puts the master valve on the discharge side of the backflow assembly, which is downstream, not upstream.
    • B Downstream of the backflow device Correct
    • C Between the meter and the isolation valve The space between the meter and the backflow assembly is where the isolation valve goes, not the master valve.
    • D At the end of the last zone The master valve controls the mainline after the backflow assembly; it is not placed at the end of a zone run.

    When a new installation has a master valve, it must go on the discharge side of the backflow prevention assembly. A master valve is optional, and the placement rule applies only when one is provided (30 TAC 344.62(h)).

    30 TAC 344.62(h)

  5. What voltage do most valve control wires carry?

    • A 24 volts AC Correct
    • B 12 volts DC The usual valve circuit runs on alternating current at about 24 volts, not 12 volts DC.
    • C 110 volts AC The valve wires carry low voltage; 110 volts is not the usual valve circuit.
    • D 220 volts AC The valve wires carry low voltage; 220 volts is not the usual valve circuit.

    The circuit from the controller out to the valves is a low-voltage circuit, and the current it sends to energize each solenoid is usually 24 volts AC. That means 110 and 220 volt figures are not the valve wire circuit.

  6. How long must an irrigator keep installation records?

    • A 6 months The rule sets three years from completion; six months is far short of it.
    • B 1 year The rule sets three years from completion, not one year.
    • C 2 years The rule sets three years from completion, not two years.
    • D 3 years Correct

    An irrigator must keep records for three years from the date the installation, maintenance, alteration, repair or service was completed (30 TAC 344.38).

    30 TAC 344.38

  7. How many hours of approved training does an irrigator need to renew the license?

    • A 8 hours No license in this group renews on 8 hours; the irrigator figure is 24.
    • B 16 hours Sixteen hours is the irrigation technician renewal figure, not the irrigator figure.
    • C 24 hours Correct
    • D 32 hours The rule sets 24 hours for an irrigator, not 32.

    Renewing an irrigator license requires 24 hours of approved training credits on top of the general renewal requirements. The 16 hour figure applies only to an irrigation technician license (30 TAC 30.122(b)).

    30 TAC 30.122(b)

  8. Backflow in a water system can be caused by:

    • A Backpressure only Backpressure is one cause, but the definition names back siphonage as a second one.
    • B Backsiphonage only Backsiphonage is one cause, but the definition names backpressure as well.
    • C Both backpressure and backsiphonage Correct
    • D Constant high pressure in the mainline Steady pressure in the mainline is normal operation and is not named as a cause of reversed flow.

    Either condition can carry irrigation water back into the potable supply, because Texas Commission on Environmental Quality (TCEQ) rules define backflow prevention as stopping a reversal of flow caused by back siphonage or by backpressure (30 TAC 344.1(3)).

    30 TAC 344.1(3)

  9. Which backflow device does TCEQ NOT allow on a new irrigation system?

    • A A pressure vacuum breaker The pressure vacuum breaker is still on the list of allowed methods where there is no backpressure.
    • B A spill-resistant vacuum breaker The spill-resistant vacuum breaker is the device the 2020 amendment added in place of the atmospheric one.
    • C A reduced pressure assembly The reduced pressure principle assembly remains an allowed method, including at a health hazard.
    • D An atmospheric vacuum breaker Correct

    The Texas Commission on Environmental Quality (TCEQ) amended its landscape irrigation rule effective July 26, 2020 to replace the atmospheric vacuum breaker (AVB) with the spill-resistant vacuum breaker, because an AVB will not work correctly with a valve downstream. Since that date the AVB is no longer an allowed method on a new system (30 TAC 344.50(b)(4)).

    30 TAC 344.50(b)(4); TCEQ, Quick Reference Guide to All Changes to 30 TAC Chapter 344 (2020), p. 18 Includes a reference document, not law.

  10. How much pressure does each foot of water height add at the bottom of a water column?

    • A 0.433 psi Correct
    • B 2.31 psi 2.31 is the number of feet of water it takes to make 1 psi, the inverse figure, not psi per foot.
    • C 0.231 psi 0.231 is the 2.31 feet-per-psi figure with the decimal point moved, not a pressure per foot.
    • D 4.33 psi 4.33 psi puts the decimal point one place off, ten times what a foot of water makes.

    A column of water 1 ft tall presses on its base with 0.433 pounds per square inch (psi), and each added foot adds the same amount. It takes 2.31 ft of water, not 1 ft, to make 1 psi, which is why 2.31 is the feet-per-psi figure.

  11. Which pipe carries water from the water source to the zone valves?

    • A The lateral A lateral runs downstream of a zone valve to the heads, not from the source to the valves.
    • B The service line The service line runs from the utility's main to the water meter, ahead of the irrigation system.
    • C The riser A riser is the short upright pipe a head sits on, not the pipe that feeds the valves.
    • D The mainline Correct

    The Texas Commission on Environmental Quality (TCEQ) defines the mainline as the irrigation pipe that delivers water from the water source to each zone valve. The laterals start at the zone valves and carry water on to the heads.

    30 TAC 344.1(28)

  12. What does the term hydraulics cover in landscape irrigation?

    • A Static and moving water, and system pressure losses Correct
    • B The chemistry and quality of the water supply Water chemistry is not part of the definition, which covers water at rest and in motion and the system's pressures.
    • C How quickly the soil takes in applied water Soil intake is a soil and scheduling subject, not what hydraulics covers.
    • D How much water the plants use each day Plant water use is evapotranspiration, not hydraulics.

    The Texas Commission on Environmental Quality (TCEQ) defines hydraulics as the science of static and dynamic water, which takes in working out an irrigation system's pressure losses and pressure needs. Soil intake, plant water use and water chemistry are separate subjects.

    30 TAC 344.1(17)

  13. What sets off water hammer in an irrigation pipe?

    • A High static pressure with no flow With no flow there is no change in velocity, so no shock wave forms.
    • B Too many heads on one zone Too many heads lowers the pressure at the heads; it does not set off a sudden change in velocity.
    • C A sudden change in water velocity Correct
    • D A long run of level pipe A straight level run carries water at a steady velocity; the source names sudden velocity changes and fittings that turn the water.

    Water hammer is a pressure surge made by shock waves, which come from a sudden rise or fall in the water's velocity, such as a valve opening or a pump starting or stopping. Pressure alone sends no shock wave because standing water has no velocity to change.

  14. Which head type covers a large open lawn with the fewest heads?

    • A Pop-up spray heads Spray heads throw only a short radius, so a large lawn needs many more of them than rotors.
    • B Bubblers A bubbler waters one small spot or basin and cannot spread water across an open lawn.
    • C Drip emitters Drip emitters wet the soil at single points, so covering a lawn with them takes far more devices than rotors.
    • D Rotor pop-ups Correct

    Because rotors throw water much farther than spray heads, each rotor covers far more ground and a large open lawn needs far fewer of them.

  15. Every drip irrigation system must include:

    • A A flow sensor A flow sensor is an optional part for spotting leaks; nothing requires one on every drip system.
    • B A master valve A master valve is installed only where the design provides one; it is not required on every drip system.
    • C A filter Correct
    • D A quick coupler A quick coupler gives hose access to system water and is not a required drip part.

    Texas A&M AgriLife's drip guide says every drip system must have a filter ahead of the emitters, because the emitters' very small openings clog with grit and sediment. That "must" is AgriLife's advice, not a Texas rule.

  16. Which of these is an emission device?

    • A A drip emitter Correct
    • B A zone valve A zone valve opens and closes a zone but applies no water itself.
    • C A backflow preventer A backflow preventer protects the drinking water supply and applies no water to the landscape.
    • D A controller A controller runs the valves on a schedule and applies no water.

    An emission device is any part that puts water onto the landscape, and the definition in 30 TAC 344.1(11) lists spray heads, rotors and drip emitters as common examples.

    30 TAC 344.1(11)

  17. Which soil takes in water most slowly?

    • A Sand Sand is coarse and takes in water quickly.
    • B Sandy loam Sandy loam is mostly sand and takes water in faster than clay.
    • C Clay Correct
    • D Loamy sand Loamy sand is coarse textured and takes in water quickly.

    Fine textured soils such as clay have small pores and low infiltration rates, while coarse sandy soils take water in fast. Clay is therefore the slowest of the four.

  18. Evapotranspiration is the water lost through:

    • A Runoff and deep drainage Runoff and deep drainage are losses from poor scheduling; evapotranspiration is evaporation plus plant use.
    • B Evaporation from soil and transpiration by plants Correct
    • C Evaporation from the spray while the heads run Water lost from the spray in the air is not the plant's need and leaves out transpiration entirely.
    • D Leaks and overspray Leaks and overspray are system faults and have nothing to do with the plant's water use.

    The plant's water requirement counts water that evaporates from the soil surface together with water the plant itself transpires, and those two together make evapotranspiration.

  19. On what basis does TCEQ require an irrigation system's zones to be separated?

    • A Plant type, microclimate, slope, soil and water needs Correct
    • B The days of the week the owner prefers to water Watering days are a schedule choice made after zoning; the rule bases zones on site and plant factors.
    • C The pipe sizes on hand Pipe size follows from the zone's flow; it is not a basis the rule gives for splitting zones.
    • D The controller's station count The controller is chosen to fit the zones, and its station count is not a basis for separating them.

    TCEQ requires separate zones based on plant material type, microclimate, topographic features, soil conditions and hydrological needs under 30 TAC 344.62(e), because each of those changes how much water an area needs.

    30 TAC 344.62(e)

  20. Which watering pattern is best for an established lawn?

    • A Light and daily Light daily watering keeps roots near the surface and wastes water to evaporation.
    • B Light, twice a day Watering lightly twice a day grows even shallower roots and loses more to evaporation.
    • C Deep and infrequent Correct
    • D Deep and daily Deep watering every day gives the soil no chance to dry and wastes water.

    Watering deeply and infrequently wets the whole root zone and lets it dry between waterings, because that grows a deeper root system that stands up to drought.

Questions about the diagnostic

What is the diagnostic?
A quick 20 scored questions check across the four exam sections that shows you how far each is from the line. About twenty minutes, untimed, no account.
How long does it take?
About twenty minutes. You get the answer and the explanation right after each question.
Is it really free?
Yes, with no account and no card. It is drawn from the 60 free questions, which are open to anyone, and the whole readout is shown.
What does the readout show?
Each section's score against the 70 percent pass mark, the line each section has to reach on its own. 30 TAC 30.20(b) sets that mark, so the line is the exam's own and not this site's.
Do I need an account?
Not for this. The result is kept in this browser, so you can come back to it on the same device. A free account keeps it anywhere and keeps what you practice afterwards.
Is IrrigatorExam connected to Texas Commission on Environmental Quality?