Which unit is used to measure water pressure?
- A GPM Gallons per minute measures flow, not pressure.
- B fps Feet per second measures velocity, not pressure.
- C psi Correct
- D in/hr Inches per hour is a precipitation rate, the depth of water put on the ground, not a pressure.
Water pressure is stated in pounds per square inch (psi) because pressure is a force spread over an area. Gallons per minute (GPM) measures flow, and feet per second (fps) measures velocity.
-
What is the pressure of water that is not moving called?
- A Dynamic pressure Dynamic pressure is measured while water is moving.
- B Static pressure Correct
- C Design pressure Design pressure is what a zone needs: the head's minimum pressure plus all losses to the source.
- D Residual pressure Residual pressure is what remains while water is being drawn, so the water is moving.
The Texas Commission on Environmental Quality (TCEQ) defines static water pressure as the pressure of water when it is not moving, and it is generally the pressure the irrigation system has available. Dynamic, or working, pressure is measured with water flowing.
30 TAC 344.1(42)
-
What does a lower C factor tell you about a pipe?
- A Its inside wall is smoother A smoother wall has a higher C factor; PVC at 150 is smoother than steel at 100.
- B Its wall is thicker The C factor rates the roughness of the inside wall, not its thickness.
- C Its inside wall is rougher Correct
- D Its pressure rating is higher The C factor says nothing about pressure rating; it rates wall roughness.
The C factor rates how rough the inside of a pipe is: a smaller C value means a rougher wall and more friction loss. Polyvinyl chloride (PVC) pipe is about 150 and standard steel about 100.
-
At what pressure does TCEQ require heads to be installed to operate?
- A The maker's recommended pressure Correct
- B The static pressure at the meter Static pressure is the supply with no water moving; heads are held to the pressure the maker publishes.
- C The pipe's pressure rating The pipe's rating is the most it can safely hold, not the pressure a head should run at.
- D 30 psi for every head No single pressure is set for every head; it depends on the maker's figure for the nozzle and spacing.
TCEQ requires emission devices to be installed to run at the optimum or recommended pressure the maker publishes for the nozzle and spacing used, under 30 TAC 344.62(c).
30 TAC 344.62(c)
-
Which pump is added to raise pressure when the supply tank is too low to deliver enough pressure?
- A A submersible well pump A submersible pump lifts water out of a well; it is not the pump added to lift the pressure a low tank gives.
- B A sump pump A sump pump empties water out of a pit, not into a supply line.
- C A metering pump A metering pump doses small measured amounts, such as a chemical, and does not raise system pressure.
- D A booster pump Correct
A tank gives pressure through the weight of its water, so a tank set too low cannot give enough. A booster pump is added in that case because it raises the pressure the tank alone can give.
-
How does each foot that water climbs on its way to a head change its pressure?
- A A loss of 0.433 psi Correct
- B A gain of 0.433 psi Water gains 0.433 psi a foot going downhill, not uphill.
- C A loss of 2.31 psi 2.31 is the feet of water in 1 psi, not the psi in 1 ft.
- D No change at all Height always changes pressure, by 0.433 psi for every foot.
Water loses 0.433 pounds per square inch (psi) for every foot it climbs because each foot of water column presses back with that much. It gains the same amount for every foot it drops, and 2.31 is the number of feet of water in 1 psi.
-
PVC irrigation piping must be designed so the water velocity does not exceed:
- A 5 fps Correct
- B 7.5 fps 7.5 fps is not the limit the rule sets for PVC irrigation piping.
- C 9 fps 9 fps is not the limit the rule sets for PVC irrigation piping.
- D 10 fps 10 fps is twice the 5 fps the rule allows in PVC irrigation piping.
The Texas Commission on Environmental Quality (TCEQ) requires polyvinyl chloride (PVC) piping in an irrigation system to be designed and installed so the water does not exceed 5 feet per second (fps). Higher figures seen in classes or other sources are not the limit the rule sets.
30 TAC 344.62(d)
-
What must all the heads in one zone have in common?
- A The same radius of throw Heads with different radii can share a zone as long as their precipitation rates match.
- B The same arc of coverage Quarter, half and full circles share zones all the time when their rates are matched.
- C The same precipitation rate Correct
- D The same nozzle flow Matched nozzles use different flows for different arcs so that the rates come out equal.
TCEQ requires every emission device in a zone to irrigate at the same precipitation rate under 30 TAC 344.62(f). Heads of different arcs, radii and flows may share a zone only when their rates match.
30 TAC 344.62(f)
-
How tall a column of water makes 1 psi at its base?
- A 0.433 ft 0.433 is the psi in 1 ft of water, not the feet in 1 psi.
- B 1.00 ft One foot of water makes only 0.433 psi, well short of 1 psi.
- C 8.34 ft 8.34 is the weight in pounds of a gallon of water, not a height.
- D 2.31 ft Correct
Each foot of water height makes 0.433 pounds per square inch (psi), so it takes 2.31 ft of water to make 1 psi. That is why psi converts to feet of head by multiplying by 2.31.
-
About how much does one gallon of water weigh?
- A 7.48 lb 7.48 is the number of gallons in a cubic foot, not the weight of a gallon.
- B 8.34 lb Correct
- C 62.4 lb 62.4 lb is what one cubic foot of water weighs, not one gallon.
- D 2.31 lb 2.31 is the feet of water in 1 psi, not a weight.
The weight of a gallon of water is about 8.34 lb. The other figures are easy to mix up because they describe a cubic foot of water, which holds 7.48 gallons and weighs 62.4 lb.
-
What is water pressure measured with the water flowing called?
- A Static pressure Static pressure is measured with no water moving.
- B Dynamic pressure Correct
- C Surge pressure Surge pressure is the spike from water hammer when flow changes suddenly, not the ordinary pressure of flowing water.
- D Design pressure Design pressure is what a zone needs: the head's minimum pressure plus all losses to the source.
Dynamic pressure, also called working pressure, is the pressure measured while water is moving through the system. It always reads below the no-flow reading at that same point because moving water loses pressure.
-
In what unit is a precipitation rate given?
- A Inches per hour Correct
- B Gallons per minute Gallons per minute measures flow through a head or a zone.
- C Gallons per hour Gallons per hour measures the flow of an emitter.
- D Inches per week Inches per week is how a weekly water need is stated, not the rate a zone applies water.
A precipitation rate is the depth of water a system puts down over time, and it is therefore given in inches per hour. Landscape rates usually sit between roughly 0.5 in/hr and something over 1.5 in/hr.
-
How must an irrigation plan used for construction be drawn?
- A To a stated scale Correct
- B Freehand with dimensions A freehand sketch with dimensions written on it does not meet the rule that the plan be drawn to scale.
- C In full color Nothing requires color; the requirement is a drawing to scale.
- D On the property survey Nothing requires the plan to sit on a survey; it must be drawn to scale and state that scale.
Every irrigation plan used for construction must be drawn to scale, and 30 TAC 344.61(c) also requires the plan to state the scale used.
30 TAC 344.61(c)
-
What is the pipe that connects the water utility's main to the water meter called?
- A Service line Correct
- B Mainline The irrigation mainline starts after the meter and carries water to the zone valves.
- C Lateral A lateral runs from a zone valve to the heads.
- D Swing pipe A swing pipe is the flexible link from a lateral to a head.
Texas public water system rules define the service line as the pipe connecting the utility's main and the water meter. The irrigation system starts on the customer's side of the meter, where the mainline carries water to the zone valves.
30 TAC 290.38(80)
-
With head-to-head spacing, how far does each head's spray reach?
- A All the way to the next head Correct
- B Halfway to the next head Spray that reaches only halfway leaves the ground between heads unwatered; head to head means reaching the next head.
- C Two-thirds of the way there Stopping short of the next head leaves a dry band, and the definition requires the spray to reach it.
- D Only to the edge of the lawn Where the spray reaches the lawn edge says nothing about coverage between heads, which is what the term describes.
Head-to-head spacing sets heads within the maker's published radius so that the spray reaches from one head to the next, as TCEQ defines it in 30 TAC 344.1(15).
30 TAC 344.1(15)
-
What other name is used for dynamic pressure?
- A Static pressure Static pressure is the pressure with no water moving, the opposite of dynamic pressure.
- B Design pressure Design pressure is what a head needs plus every loss back to the source, a figure worked out on paper rather than another name for flowing pressure.
- C Test pressure Test pressure is the pressure a line is held at to check it for leaks, not the pressure of water moving through the system.
- D Working pressure Correct
Dynamic pressure is the pressure while water is flowing through the system, and the term working pressure means the same thing, since it is the pressure the system has while it works.
-
Velocity, the speed of water moving through a pipe, is measured in which unit?
- A GPM Gallons per minute measures flow, the amount of water, not its speed.
- B fps Correct
- C psi Pounds per square inch measures pressure, not speed.
- D GPH Gallons per hour measures flow, usually for drip emitters, not speed.
Velocity takes feet per second (fps) as its unit because it is how fast the water moves, a distance covered in a set time. Flow takes gallons per minute (GPM), and pressure takes pounds per square inch (psi).
-
Design flow through a water meter should be held to no more than ____ of the meter's maximum safe flow.
- A 10 percent 10 percent is the meter guideline for pressure loss against static pressure, not for flow.
- B 50 percent 50 percent is not the figure the guideline sets; it allows up to 75 percent.
- C 75 percent Correct
- D 90 percent 90 percent is above the 75 percent the guideline allows.
Design flow through a meter should stay at or under 75 percent of the meter's maximum safe flow, which the meter's own chart gives. That figure is a design guideline from model irrigation standards, not a rule of the Texas Commission on Environmental Quality (TCEQ).
-
How many members sit on the Irrigator Advisory Council?
- A 7 members The council has nine members, not seven.
- B 9 members Correct
- C 11 members The council has nine members, not eleven.
- D 12 members The council has nine members, not twelve.
The Irrigator Advisory Council has nine members, a number the rule sets, all appointed by the Texas Commission on Environmental Quality (TCEQ): six must be licensed irrigators and three represent the public (30 TAC 344.80(a) to (c)).
30 TAC 344.80(a)
-
How many hours of approved training does an irrigator need to renew the license?
- A 8 hours No license in this group renews on 8 hours; the irrigator figure is 24.
- B 16 hours Sixteen hours is the irrigation technician renewal figure, not the irrigator figure.
- C 24 hours Correct
- D 32 hours The rule sets 24 hours for an irrigator, not 32.
Renewing an irrigator license requires 24 hours of approved training credits on top of the general renewal requirements. The 16 hour figure applies only to an irrigation technician license (30 TAC 30.122(b)).
30 TAC 30.122(b)
-
On a system designated a health hazard, the backflow assembly must be tested:
- A Only when installed A test on installation alone is the minimum for a non-health hazard system; a health hazard system adds a yearly test.
- B Once every three years Three years is the term of an irrigator license, not the testing interval.
- C At least once a year Correct
- D Only after a repair A test follows any repair, but a health hazard assembly must also be tested every year.
Assemblies on irrigation systems designated as health hazards must be tested annually, on top of the test every assembly gets on installation, repair, replacement or relocation (30 TAC 344.50(e)).
30 TAC 344.50(e)
-
Backflow in a water system can be caused by:
- A Backpressure only Backpressure is one cause, but the definition names back siphonage as a second one.
- B Backsiphonage only Backsiphonage is one cause, but the definition names backpressure as well.
- C Both backpressure and backsiphonage Correct
- D Constant high pressure in the mainline Steady pressure in the mainline is normal operation and is not named as a cause of reversed flow.
Either condition can carry irrigation water back into the potable supply, because Texas Commission on Environmental Quality (TCEQ) rules define backflow prevention as stopping a reversal of flow caused by back siphonage or by backpressure (30 TAC 344.1(3)).
30 TAC 344.1(3)
-
Heads and piping set well above the backflow device can cause backflow by:
- A Backpressure Correct
- B Backsiphonage Backsiphonage comes from a drop in supply pressure that pulls water back; raised piping pushes water back from downstream.
- C Water hammer Water hammer is a pressure surge when flow stops suddenly, not the steady push from piping set above the device.
- D Thermal expansion Thermal expansion comes from heated water; raised heads and piping add pressure by their height, not by heat.
Backpressure is any rise in downstream pressure above the supply pressure, and the Texas Commission on Environmental Quality (TCEQ) guide RG-478 names elevation of piping as one cause alongside a pump. Heads and piping set high above the device therefore push water back toward the supply rather than pulling it.
RG-478, p. 6 Reference document, not law.
-
How high above ground must an RP be installed?
- A At least 6 in Six inches was the old atmospheric vacuum breaker height; the reduced pressure assembly needs 12 inches.
- B At least 12 in Correct
- C At least 18 in The minimum is 12 inches above ground, not 18.
- D At least 24 in The minimum is 12 inches above ground, not 24.
A reduced pressure principle assembly (RP) must be installed at least 12 inches above ground in a place where it cannot be submerged, and drainage must be provided for water its relief valve discharges (30 TAC 344.50(b)(2)).
30 TAC 344.50(b)(2)(A)
-
An air gap must be at least twice the outlet diameter and never less than:
- A 1 in Correct
- B 2 in The floor is 1 inch; a 2 inch gap is only the minimum for a 1 inch outlet.
- C 6 in Six inches was the old atmospheric vacuum breaker height, not the air gap floor.
- D 12 in Twelve inches is a vacuum breaker and reduced pressure assembly height, not the air gap floor.
The vertical separation of an air gap must be at least twice the diameter of the supply outlet, and it may never be less than 1.0 inch whatever size the outlet is (30 TAC 344.1(1)).
30 TAC 344.1(1)
-
On a new system, the isolation valve is installed:
- A Between the meter and the backflow device Correct
- B Downstream of the master valve The master valve sits downstream of the backflow assembly; the isolation valve belongs upstream of the assembly, after the meter.
- C At each zone valve Zone valves control single zones; the rule places the isolation valve between the meter and the backflow assembly.
- D Upstream of the water meter The rule puts the isolation valve after the meter, between it and the backflow assembly, not ahead of the meter.
Every new irrigation system must include an isolation valve between the water meter and the backflow prevention assembly, so the valve sits after the meter and ahead of the assembly (30 TAC 344.62(k)).
30 TAC 344.62(k)
-
Water that is suitable for people to drink is called:
- A Reclaimed water Reclaimed water is treated wastewater and is listed as a non-potable source.
- B Non-potable water Non-potable water is defined as water not suitable for human consumption.
- C Graywater Graywater is household wastewater and is listed as a non-potable source.
- D Potable water Correct
Potable water means water suitable for human consumption that meets the definition of drinking water (30 TAC 344.1(37)). Reclaimed water and graywater are both listed as non-potable sources and are not fit to drink.
30 TAC 344.1(37)
-
Which backflow device may be set below ground?
- A A reduced pressure assembly A reduced pressure principle assembly must be installed at least 12 inches above ground where it cannot be submerged.
- B A pressure vacuum breaker A pressure vacuum breaker must be at least 12 inches above all downstream piping and the highest downstream opening.
- C A double check assembly Correct
- D A spill-resistant vacuum breaker A spill-resistant vacuum breaker carries the same 12 inch height rule as the pressure vacuum breaker.
The rule sets below-ground installation requirements only for double check valve assemblies (30 TAC 344.50(d)). The reduced pressure assembly must sit at least 12 inches above ground, and the vacuum breakers at least 12 inches above the highest downstream opening. A city may still bar the double check locally.
30 TAC 344.50(d)
-
Where the maker gives no depth figure, irrigation pipe needs a minimum cover of:
- A 2 in Two inches is the reduced cover allowed only where a utility, a structure or roots make the 6 inch cover impractical.
- B 6 in Correct
- C 12 in The state minimum is 6 inches of select backfill; no 12 inch cover is set for irrigation pipe.
- D 18 in The state minimum is 6 inches of select backfill; no 18 inch cover is set for irrigation pipe.
Where the manufacturer publishes no depth coverage figure, piping must have at least 6 inches of select backfill between the top of the topmost pipe and the natural grade (30 TAC 344.62(l)(1)). The 2 inch figure applies only where a utility, a structure or roots make the 6 inch cover impractical (30 TAC 344.62(l)(2)).
30 TAC 344.62(l)(1) and (l)(2)
-
Which backflow device does TCEQ NOT allow on a new irrigation system?
- A A pressure vacuum breaker The pressure vacuum breaker is still on the list of allowed methods where there is no backpressure.
- B A spill-resistant vacuum breaker The spill-resistant vacuum breaker is the device the 2020 amendment added in place of the atmospheric one.
- C A reduced pressure assembly The reduced pressure principle assembly remains an allowed method, including at a health hazard.
- D An atmospheric vacuum breaker Correct
The Texas Commission on Environmental Quality (TCEQ) amended its landscape irrigation rule effective July 26, 2020 to replace the atmospheric vacuum breaker (AVB) with the spill-resistant vacuum breaker, because an AVB will not work correctly with a valve downstream. Since that date the AVB is no longer an allowed method on a new system (30 TAC 344.50(b)(4)).
30 TAC 344.50(b)(4); TCEQ, Quick Reference Guide to All Changes to 30 TAC Chapter 344 (2020), p. 18 Includes a reference document, not law.
-
How long must an irrigator keep installation records?
- A 6 months The rule sets three years from completion; six months is far short of it.
- B 1 year The rule sets three years from completion, not one year.
- C 2 years The rule sets three years from completion, not two years.
- D 3 years Correct
An irrigator must keep records for three years from the date the installation, maintenance, alteration, repair or service was completed (30 TAC 344.38).
30 TAC 344.38
-
What voltage do most valve control wires carry?
- A 24 volts AC Correct
- B 12 volts DC The usual valve circuit runs on alternating current at about 24 volts, not 12 volts DC.
- C 110 volts AC The valve wires carry low voltage; 110 volts is not the usual valve circuit.
- D 220 volts AC The valve wires carry low voltage; 220 volts is not the usual valve circuit.
The circuit from the controller out to the valves is a low-voltage circuit, and the current it sends to energize each solenoid is usually 24 volts AC. That means 110 and 220 volt figures are not the valve wire circuit.
-
According to TCEQ, where does a master valve go when one is installed on a new system?
- A Upstream of the backflow device The rule puts the master valve on the discharge side of the backflow assembly, which is downstream, not upstream.
- B Downstream of the backflow device Correct
- C Between the meter and the isolation valve The space between the meter and the backflow assembly is where the isolation valve goes, not the master valve.
- D At the end of the last zone The master valve controls the mainline after the backflow assembly; it is not placed at the end of a zone run.
When a new installation has a master valve, it must go on the discharge side of the backflow prevention assembly. A master valve is optional, and the placement rule applies only when one is provided (30 TAC 344.62(h)).
30 TAC 344.62(h)
-
Which valve turns a single zone on and off?
- A The master valve A master valve controls the flow of water to the whole mainline, not one zone.
- B The isolation valve An isolation valve shuts off the supply between the meter and the backflow assembly; it does not run a zone.
- C The zone valve Correct
- D The quick coupler valve A quick coupler valve gives hose or key access to water; it does not switch a zone on and off.
A zone valve is the automatic valve that controls only a single zone of the system. A master valve controls flow to the whole mainline instead (30 TAC 344.1(47)).
30 TAC 344.1(47)
-
The water a well-drained soil still holds after the free water has drained away by gravity is called:
- A The wilting point The wilting point is the low end, the water content at which most plants can no longer draw enough water.
- B Saturation Saturation is the soil before the free water drains, with its pores full.
- C Available water Available water is only the part plants can take up, which stops at the wilting point, not all the water left after draining.
- D Field capacity Correct
Field capacity is the water a well-drained soil holds once gravity has drained the free water out, and it sets the top of the range plants draw on. A sandy soil reaches it within hours, while a clay can take several days.
NRCS NEH Part 652, Irrigation Guide, p. 2-4 Reference document, not law.
-
Which soil takes in water most slowly?
- A Sand Sand is coarse and takes in water quickly.
- B Sandy loam Sandy loam is mostly sand and takes water in faster than clay.
- C Clay Correct
- D Loamy sand Loamy sand is coarse textured and takes in water quickly.
Fine textured soils such as clay have small pores and low infiltration rates, while coarse sandy soils take water in fast. Clay is therefore the slowest of the four.
-
Which of these is an emission device?
- A A drip emitter Correct
- B A zone valve A zone valve opens and closes a zone but applies no water itself.
- C A backflow preventer A backflow preventer protects the drinking water supply and applies no water to the landscape.
- D A controller A controller runs the valves on a schedule and applies no water.
An emission device is any part that puts water onto the landscape, and the definition in 30 TAC 344.1(11) lists spray heads, rotors and drip emitters as common examples.
30 TAC 344.1(11)
-
Every drip irrigation system must include:
- A A flow sensor A flow sensor is an optional part for spotting leaks; nothing requires one on every drip system.
- B A master valve A master valve is installed only where the design provides one; it is not required on every drip system.
- C A filter Correct
- D A quick coupler A quick coupler gives hose access to system water and is not a required drip part.
Texas A&M AgriLife's drip guide says every drip system must have a filter ahead of the emitters, because the emitters' very small openings clog with grit and sediment. That "must" is AgriLife's advice, not a Texas rule.
-
In what unit is the flow in an irrigation system measured?
- A fps Feet per second measures velocity, how fast the water moves, not how much of it flows.
- B psi Pounds per square inch measures pressure, not flow.
- C GPM Correct
- D Feet of head Feet of head is another way to state pressure, not flow.
Flow is a volume of water delivered in a set time, so it takes gallons per minute (GPM) as its unit. Speed of the water takes feet per second (fps), and pressure takes pounds per square inch (psi) or feet of head.
-
Evapotranspiration is the water lost through:
- A Runoff and deep drainage Runoff and deep drainage are losses from poor scheduling; evapotranspiration is evaporation plus plant use.
- B Evaporation from soil and transpiration by plants Correct
- C Evaporation from the spray while the heads run Water lost from the spray in the air is not the plant's need and leaves out transpiration entirely.
- D Leaks and overspray Leaks and overspray are system faults and have nothing to do with the plant's water use.
The plant's water requirement counts water that evaporates from the soil surface together with water the plant itself transpires, and those two together make evapotranspiration.
-
Which head type covers a large open lawn with the fewest heads?
- A Pop-up spray heads Spray heads throw only a short radius, so a large lawn needs many more of them than rotors.
- B Bubblers A bubbler waters one small spot or basin and cannot spread water across an open lawn.
- C Drip emitters Drip emitters wet the soil at single points, so covering a lawn with them takes far more devices than rotors.
- D Rotor pop-ups Correct
Because rotors throw water much farther than spray heads, each rotor covers far more ground and a large open lawn needs far fewer of them.
-
How is the design pressure for an irrigation zone worked out?
- A The static pressure measured at the water meter Static pressure at the meter is what the site has available, not what the zone needs.
- B The head's minimum pressure plus all losses to the source Correct
- C The static pressure less every loss to the head Static pressure less the losses is the working pressure that reaches the head, not the design pressure.
- D The pressure rating printed on the pipe A pipe's rating is the most it may hold, not the pressure the heads need.
The Texas Commission on Environmental Quality (TCEQ) defines design pressure as the emission device's minimum operating pressure added to every pressure loss between that device and the water source. It is the pressure the source must supply for the head to work properly.
30 TAC 344.1(9)
-
What sets off water hammer in an irrigation pipe?
- A High static pressure with no flow With no flow there is no change in velocity, so no shock wave forms.
- B Too many heads on one zone Too many heads lowers the pressure at the heads; it does not set off a sudden change in velocity.
- C A sudden change in water velocity Correct
- D A long run of level pipe A straight level run carries water at a steady velocity; the source names sudden velocity changes and fittings that turn the water.
Water hammer is a pressure surge made by shock waves, which come from a sudden rise or fall in the water's velocity, such as a valve opening or a pump starting or stopping. Pressure alone sends no shock wave because standing water has no velocity to change.
-
Head spacing may differ from the maker's published radius or spacing by no more than:
- A 5 percent 5 percent is tighter than the rule; spacing may vary by up to 10 percent.
- B 10 percent Correct
- C 20 percent 20 percent is twice the tolerance the rule allows.
- D 25 percent 25 percent is well past the plus or minus 10 percent the rule allows.
Since the amendment effective July 26, 2020, 30 TAC 344.62(b)(1) lets head spacing vary by up to plus or minus 10 percent of the maker's published radius or spacing and no further.
30 TAC 344.62(b)(1)
-
What does the term hydraulics cover in landscape irrigation?
- A Static and moving water, and system pressure losses Correct
- B The chemistry and quality of the water supply Water chemistry is not part of the definition, which covers water at rest and in motion and the system's pressures.
- C How quickly the soil takes in applied water Soil intake is a soil and scheduling subject, not what hydraulics covers.
- D How much water the plants use each day Plant water use is evapotranspiration, not hydraulics.
The Texas Commission on Environmental Quality (TCEQ) defines hydraulics as the science of static and dynamic water, which takes in working out an irrigation system's pressure losses and pressure needs. Soil intake, plant water use and water chemistry are separate subjects.
30 TAC 344.1(17)
-
On what basis does TCEQ require an irrigation system's zones to be separated?
- A Plant type, microclimate, slope, soil and water needs Correct
- B The days of the week the owner prefers to water Watering days are a schedule choice made after zoning; the rule bases zones on site and plant factors.
- C The pipe sizes on hand Pipe size follows from the zone's flow; it is not a basis the rule gives for splitting zones.
- D The controller's station count The controller is chosen to fit the zones, and its station count is not a basis for separating them.
TCEQ requires separate zones based on plant material type, microclimate, topographic features, soil conditions and hydrological needs under 30 TAC 344.62(e), because each of those changes how much water an area needs.
30 TAC 344.62(e)
-
How much pressure does each foot of water height add at the bottom of a water column?
- A 0.433 psi Correct
- B 2.31 psi 2.31 is the number of feet of water it takes to make 1 psi, the inverse figure, not psi per foot.
- C 0.231 psi 0.231 is the 2.31 feet-per-psi figure with the decimal point moved, not a pressure per foot.
- D 4.33 psi 4.33 psi puts the decimal point one place off, ten times what a foot of water makes.
A column of water 1 ft tall presses on its base with 0.433 pounds per square inch (psi), and each added foot adds the same amount. It takes 2.31 ft of water, not 1 ft, to make 1 psi, which is why 2.31 is the feet-per-psi figure.
-
How is a drip zone's total emitter flow in GPH turned into GPM?
- A Multiply it by 60 Multiplying by 60 turns gallons per minute into gallons per hour, the opposite direction.
- B Divide it by 100 An hour holds 60 minutes, not 100, so dividing by 100 gives too small a flow.
- C Divide it by 60 Correct
- D Divide it by 24 Dividing by 24 turns a daily figure into an hourly one; it never reaches minutes.
Because an hour holds 60 minutes, a drip zone's flow in gallons per hour (GPH) becomes gallons per minute (GPM) when it is divided by 60. Multiplying by 60 goes the other way, from GPM to GPH.
-
Which watering pattern is best for an established lawn?
- A Light and daily Light daily watering keeps roots near the surface and wastes water to evaporation.
- B Light, twice a day Watering lightly twice a day grows even shallower roots and loses more to evaporation.
- C Deep and infrequent Correct
- D Deep and daily Deep watering every day gives the soil no chance to dry and wastes water.
Watering deeply and infrequently wets the whole root zone and lets it dry between waterings, because that grows a deeper root system that stands up to drought.
-
Which pipe carries water from the water source to the zone valves?
- A The lateral A lateral runs downstream of a zone valve to the heads, not from the source to the valves.
- B The service line The service line runs from the utility's main to the water meter, ahead of the irrigation system.
- C The riser A riser is the short upright pipe a head sits on, not the pipe that feeds the valves.
- D The mainline Correct
The Texas Commission on Environmental Quality (TCEQ) defines the mainline as the irrigation pipe that delivers water from the water source to each zone valve. The laterals start at the zone valves and carry water on to the heads.
30 TAC 344.1(28)
-
On a new system, above-ground spray may not water a strip with paving on two sides if the strip is narrower than:
- A 24 in 24 in is half the limit; strips from 24 in up to just under 48 in are barred as well.
- B 36 in 36 in is still under the limit, so the bar reaches strips wider than 36 in too.
- C 48 in Correct
- D 60 in The limit is 48 in; a strip 48 in or wider may use spray.
New systems may not use above-ground spray devices in landscapes less than 48 inches wide or long, not counting the paving, that have walk or drive paving along two or more sides, under 30 TAC 344.62(b)(2).
30 TAC 344.62(b)(2)
-
An RP on a new system has just been tested. Within what time must the results reach the local water purveyor?
- A 5 business days The rule allows ten business days, not five.
- B 10 business days Correct
- C 10 calendar days The period is counted in business days, not calendar days.
- D 30 calendar days The rule allows ten business days, well short of thirty calendar days.
The irrigator must make sure the assembly is tested before the system goes into service and that the results reach the local water purveyor within ten business days of the test (30 TAC 344.52(c)).
30 TAC 344.52(c)
-
What condition creates backpressure?
- A Downstream pressure above supply pressure Correct
- B Supply pressure dropping below atmospheric Supply pressure falling below atmospheric is the definition of backsiphonage.
- C Heavy use at a nearby fire hydrant Heavy hydrant use lowers pressure in the mains, which causes backsiphonage.
- D An undersized water meter An undersized meter causes pressure loss on the way in; it does not raise pressure downstream above the supply.
Backpressure requires downstream pressure that overcomes the supply pressure and pushes water back toward the source. A drop in supply pressure, such as heavy hydrant use, pulls water back instead, and that is backsiphonage.
RG-478, p. 7 Reference document, not law.
-
A PVB must be installed at least:
- A 12 in above the highest downstream head Correct
- B 6 in above the highest downstream sprinkler Six inches above the outlets was the atmospheric vacuum breaker's height, not the pressure vacuum breaker's.
- C 12 in above the ground Twelve inches above ground is the reduced pressure principle assembly's rule; the pressure vacuum breaker is measured from the highest head.
- D Below grade in a valve box Only the double check may be installed below ground.
A pressure vacuum breaker (PVB) must sit at least 12 inches above all downstream piping and the highest downstream opening (30 TAC 344.50(b)(3)(B)). Its height is measured against the heads it serves, not against the ground.
30 TAC 344.50(b)(3)(B)
-
What causes backsiphonage?
- A A booster pump on the system A pump raises downstream pressure, which is listed as a cause of backpressure.
- B Heads set above the backflow device Raised piping and heads add elevation pressure downstream, which is a cause of backpressure.
- C A vacuum in the water supply line Correct
- D Downstream pressure above supply pressure Downstream pressure above the supply is the definition of backpressure.
Backsiphonage is backflow caused by supply pressure dropping below atmospheric pressure, because the vacuum in the supply line then pulls water back from the irrigation side. Pumps, raised heads and higher downstream pressure push water back instead, and that is backpressure.
RG-478, p. 5 Reference document, not law.
-
Why is PVC pipe laid in a slight snake pattern in the trench?
- A To allow for expansion and contraction Correct
- B To lower friction loss in the line Extra bends add length, so snaking does not lower friction loss.
- C To raise the water velocity Snaking the pipe does nothing to raise velocity; its purpose is movement with temperature.
- D To keep the control wire centered The guide lays wire beside the pipe; snaking the pipe is for expansion and contraction.
Laying the pipe in a serpentine pattern before backfilling leaves slack so that the pipe can expand and contract in the trench.
UFGS 32 84 23, Underground Sprinklers, p. 20 Reference document, not law.
-
What must a public water system be physically linked to for a cross-connection to exist?
- A A fire hydrant on the same main A fire hydrant is part of the public water system, not another source of water.
- B A second meter on the same service A second meter still carries potable water from the same system.
- C A water source of questionable quality Correct
- D A pressure regulator at the house A pressure regulator carries the same potable water and adds no other source.
A cross-connection exists only where a public water system is linked to a supply of unknown or questionable quality, a source that may contain contaminants, or water treated to a lesser degree (30 TAC 344.1(7)). Hydrants, meters and regulators are parts of the potable system itself and bring in no other source.
30 TAC 344.1(7)
-
A licensed irrigation technician works under the supervision of:
- A A licensed irrigator Correct
- B An irrigation inspector An inspector enforces local rules and checks the work; he does not supervise the technician.
- C A backflow tester A backflow tester tests assemblies; the rule gives supervision of a technician to a licensed irrigator.
- D The property owner The owner is the customer; the rule requires a licensed irrigator to supervise the technician.
An irrigation technician installs, maintains, alters, repairs or services systems only under the supervision of a licensed irrigator (30 TAC 344.30(b)(2)).
30 TAC 344.30(b)(2)
-
What is a group of zone valves installed together in one spot called?
- A A header A header is a pipe feeding several outlets, not a grouping of control valves.
- B A loop A loop is a pipe layout that feeds from both ends, not a grouping of control valves.
- C A manifold Correct
- D A swing joint A swing joint connects a head to a lateral; it has nothing to do with grouping valves.
A manifold means control valves grouped side by side in one area rather than spread across the site. A header, a loop and a swing joint are piping terms, not a valve grouping.
-
Who may approve a change from the irrigation plan during installation?
- A The irrigation technician The rule gives the power to authorize plan changes to the licensed irrigator, not the technician.
- B The licensed irrigator Correct
- C The property owner The owner may ask for a change, but the rule gives the authorization to the licensed irrigator.
- D The city inspector The inspector checks the work; the rule gives the authorization to the licensed irrigator.
During installation the licensed irrigator authorizes changes from the original plan, and each change must be documented in red ink on the plan. The change also must not weaken the system or break a rule (30 TAC 344.61(d)).
30 TAC 344.61(d)