Elevation and pressure: 0.433 psi and 2.31 ft

One foot of water is 0.433 psi and one psi is 2.31 ft of head. Worked for static pressure uphill and downhill, and for design pressure under 30 TAC 344.1(9).

Published 2026-11-02

One foot of water is 0.433 pounds per square inch (psi), and it takes 2.31 feet of water to make 1 psi. So a head 23 ft above the water meter sees 23 × 0.433 = 9.96 psi less static pressure than the meter does, and a gauge reading of 53 psi is 53 × 2.31 = 122.4 ft of head.

Both figures are in the conversion table of the US Natural Resources Conservation Service (NRCS) Irrigation Guide, Part 652 (Exhibit 16-1, p. 16-2), which sets 1 pound per square inch equal to “2.31 feet of head of water” and “1 foot head of water (ft) = 0.433 pounds per square inch”.

Where do the two numbers come from?

The Pennsylvania supplement to Part 652 derives 2.31 ft per psi from the weight of water, 62.4 pounds per cubic foot, and the 144 square inches in a square foot, and gives the reverse as 0.43 psi/ft (equation 6.13, p. PA6-17):

  • 144 ÷ 62.4 = 2.3077, which is 2.31 ft per psi.
  • 62.4 ÷ 144 = 0.4333, which is 0.433 psi per ft.

They are the same fact turned round: 1 ÷ 2.31 = 0.4329, and 0.433 × 2.31 = 1.0002. Going from feet to psi, multiply by 0.433 or divide by 2.31. Going from psi to feet, multiply by 2.31 or divide by 0.433. The supplement’s own example: a water tower 70 ft high gives “70 ft/2.31 ft/psi = 30 psi” at its base, and “This relationship is the connection between elevation and pressure.”

Each example below is worked both ways, and the two agree to two decimal places in psi and to one in feet.

How does a head above the meter change static pressure?

30 TAC 344.1(42) defines static water pressure as “The pressure of water when it is not moving” and adds that “Generally, this is the pressure available to the irrigation system.” Water standing in the pipe loses that pressure as it climbs.

A meter with 71 psi static, and a rotor zone on a rise whose heads sit 23 ft above the meter.

  1. Elevation loss: 23 × 0.433 = 9.959 psi (or 23 ÷ 2.31 = 9.957 psi).
  2. Static at the heads: 71 − 9.959 = 61.041.

Static pressure at the heads = 61.04 psi either way.

The slip to watch is using the wrong factor: 23 × 2.31 = 53.13 “psi” is a height in feet treated as pressure, and it leaves 17.87 psi at the heads.

And a head below the meter?

The water gains pressure going down by the same amount per foot. NRCS Part 623, Chapter 11, works a lateral laid downhill around the “pressure gain due to elevation decrease” (NEH 623, Chapter 11, sample calculation 11-8, p. 11-96).

The same 71 psi meter, and a bed 19 ft below it.

  1. Elevation gain: 19 × 0.433 = 8.227 psi (or 19 ÷ 2.31 = 8.225 psi).
  2. Static at the bed: 71 + 8.227 = 79.227.

Static pressure at the bed = 79.23 psi.

How is a gauge reading turned into feet of head?

Multiply by 2.31. A static reading of 53 psi:

  • 53 × 2.31 = 122.43 ft.
  • 53 ÷ 0.433 = 122.40 ft.

Head = 122.4 ft.

Where does elevation go in design pressure?

30 TAC 344.1(9) defines design pressure as “the sum of the minimum operating pressure of an emission device to the total of all pressure losses accumulated from the emission device to the water source.” A climb from the source to the head is one of those losses, and the irrigation plan has to show the result: 344.61(c)(9) lists “the design pressure” among what a plan must include.

The NRCS handbook adds the climb up a riser the same way: the pressure needed “to lift water up the riser” is “riser height/2.31” (Part 623, Chapter 11, p. 11-93). A 3 ft riser takes 3 ÷ 2.31 = 1.30 psi (or 3 × 0.433 = 1.30 psi).

A worked chain, with every loss but the elevation given:

  • The head farthest from the meter needs at least 30 psi to run.
  • Losses along the way: meter 3.1 psi, backflow assembly 7.5 psi, pipe and fittings 5.3 psi, zone valve 2.3 psi. Those add to 18.2 psi.
  • That head sits 17 ft above the meter: 17 × 0.433 = 7.361 psi (or 17 ÷ 2.31 = 7.359 psi).
  1. 30 + 18.2 = 48.2 psi.
  2. 48.2 + 7.361 = 55.561.

Design pressure = 55.56 psi either way. With 61 psi static at the meter, that leaves 61 − 55.56 = 5.44 psi in hand. Treating the 17 ft as 17 × 2.31 = 39.27 psi instead gives 87.47 psi, which no 61 psi supply could meet. More worked pressure items are in the Hydraulics practice questions.

Had the same head sat 17 ft below the meter, the fall would be a gain, as in the NRCS downhill example, and the 7.361 psi would come off instead: 48.2 − 7.361 = 40.84 psi.