IrrigatorExam

Guide

Friction loss and the 5 ft/s limit in PVC

30 TAC 344.62(d) holds PVC to 5 ft/s. Velocity and friction loss worked from this site's Hazen-Williams table by pipe size and class, beside a printed chart.

Published 2026-11-09

Water in PVC irrigation pipe may not move faster than 5 feet per second (ft/s), under 30 TAC 344.62(d). On this site’s friction-loss table, 10 gallons per minute (GPM) runs at 3.71 ft/s in 1 in Schedule 40 PVC and loses 2.39 psi per 100 ft, so 135 ft of that pipe loses 3.23 psi.

The table is this site’s own, worked from the Hazen-Williams formula with the inputs the US Natural Resources Conservation Service (NRCS) publishes, at every whole GPM. Every figure below is read at an exact row of it.

What does 344.62(d) say?

30 TAC 344.62(d), in full: “Piping. Polyvinyl chloride (PVC) piping in irrigation systems must be designed and installed so that the flow of water in the pipe will not exceed a velocity of five feet per second.”

The rule names PVC and one number. Figures of 7.5 and 9 ft/s that some license classes teach are class conventions, not the rule.

Where do the velocity figures come from?

From the flow and the pipe’s inside diameter. NRCS Part 623, Chapter 7 gives the average velocity as a constant times the flow over the inside diameter squared, with the constant 0.409 for flow in GPM, diameter in inches and velocity in ft/s (equation 7-54, p. 7-116). Its worked example writes the constant as 0.4085, and this site’s table uses that.

Pipe class matters because it sets the inside diameter. The same nominal 1 in pipe is 1.189 in inside as Class 200 and 1.049 in as Schedule 40, by the tables in the Pennsylvania supplement to the NRCS Irrigation Guide (Tables B-2 and B-3). Through the smaller Schedule 40 bore the same flow moves faster.

Which pipe carries 26 GPM under 5 ft/s?

A zone of 26 GPM, read at the 26 GPM row:

PipeVelocityUnder 5 ft/s?
Class 200, 1 in7.51 ft/sNo
Schedule 40, 1-1/4 in5.58 ft/sNo
Class 200, 1-1/4 in4.71 ft/sYes

Checked by the formula for the last row: 0.4085 × 26 ÷ 1.502² = 0.4085 × 26 ÷ 2.2560 = 4.71 ft/s.

What is the most a size can carry?

Go down the velocity column to the last row at or under 5.00:

  • 1-1/4 in Class 200: 27 GPM is 4.89 ft/s and 28 GPM is 5.07 ft/s, so 27 GPM.
  • 1-1/4 in Schedule 40: 23 GPM is 4.93 ft/s and 24 GPM is 5.15 ft/s, so 23 GPM.
  • 1 in Schedule 40: 13 GPM is 4.83 ft/s and 14 GPM is 5.20 ft/s, so 13 GPM.

The formula turned round gives the same whole numbers: 5 × 1.502² ÷ 0.4085 = 27.61 GPM, 5 × 1.380² ÷ 0.4085 = 23.31 GPM, and 5 × 1.049² ÷ 0.4085 = 13.47 GPM. A single “most GPM” figure for a nominal size cannot hold for both classes of it: the two 1-1/4 in pipes above, Class 200 and Schedule 40, differ by 4 GPM.

How is friction loss read off the table?

The table’s losses come from the Hazen-Williams equation as NRCS Part 623, Chapter 7, prints it (equation 7-48, p. 7-113), worked at C = 150, the friction coefficient the Pennsylvania supplement’s PVC tables state. Part 623 says C = 150 has typically been used for plastic pipe, but it also says the formula with C = 150 underestimates the friction in small pipe, and its Table 7-23 recommends 130 for pipe up to 1 in, 140 for pipe under 3 in and 150 for 3 in and larger. Each cell is psi lost per 100 ft of pipe.

135 ft of 1 in Schedule 40 carrying 10 GPM:

  1. Row: 2.39 psi per 100 ft.
  2. 2.39 × 135 ÷ 100 = 3.2265.

Friction loss = 3.23 psi.

The same run in 1-1/4 in Schedule 40 reads 0.63 psi per 100 ft at 10 GPM: 0.63 × 1.35 = 0.85 psi, at 2.15 ft/s.

The common slip is to stop at step 1 and give 2.39 psi, the loss for 100 ft, as the loss for the whole 135 ft. Worked practice items on the table are in the Hydraulics practice questions.

Why can a printed chart give a different answer?

The Pennsylvania supplement’s own Table B-3 prints the same pipe, Schedule 40 with C = 150. For 1 in, its 10 GPM row gives 3.70 ft/s and 2.40 psi per 100 ft, where this site’s table gives 3.71 and 2.39. Read off Table B-3, the 135 ft run loses 2.40 × 1.35 = 3.24 psi instead of 3.23. Table B-3 also prints rows only at 1, 2, 4, 6, 8, 10, 15 and 20 GPM and on up, so a flow such as 13 GPM has no row of its own there.

Charts from pipe makers and the Irrigation Association’s 2008 friction loss chart for Class 200 and Schedule 40 print their own rows and their own inside diameters, and their figures for the same nominal pipe are not always this table’s.