A precipitation rate (PR), in inches per hour, is 96.3 times the flow in gallons per minute (GPM) divided by the area that flow waters, in square feet. Full-circle heads flowing 3.9 GPM each, set on a 17 by 17 ft square, put down 96.3 × 3.9 ÷ 289 = 1.30 in/hr.
PR is the depth of water a layout of sprinklers puts down in an hour. The US Natural Resources Conservation Service (NRCS) works it out in its National Engineering Handbook, Part 623, Chapter 11, by “dividing the discharge by the mean area per sprinkler” and multiplying by a constant of 96.3 (equation 11-16, p. 11-40). Written out for a grid of alike heads, with the spacings in feet:
PR (in/hr) = 96.3 × GPM per head ÷ (spacing along the row × spacing between rows)
The same equation appears in the NRCS Irrigation Guide, Part 652 (p. 9-40), which calls 96.3 the “units conversion factor when using gallons per minute and sprinkler head spacing in feet”.
Where does 96.3 come from?
One gallon is 231 cubic inches (Part 652, Exhibit 16-1, p. 16-1). A flow of 1 GPM for an hour is 60 gallons, or 60 × 231 = 13,860 cubic inches. Spread over one square foot, which is 12 × 12 = 144 square inches, that is 13,860 ÷ 144 = 96.25 inches. The handbooks round it to 96.3.
The rounding does not move an answer given to two decimal places in any of the examples below. Each one is worked with 96.3 and checked with 96.25.
How is it worked on square spacing?
Full-circle spray heads set 17 ft apart along each row, with the rows 17 ft apart, each head flowing 3.9 GPM.
- Area per head: 17 × 17 = 289 sq ft.
- 96.3 × 3.9 = 375.57.
- 375.57 ÷ 289 = 1.2996.
PR = 1.30 in/hr. With 96.25: 96.25 × 3.9 = 375.375, and 375.375 ÷ 289 = 1.2989, which is also 1.30 in/hr.
How is it worked on rectangular spacing?
Full-circle rotors 34 ft apart along each row, with the rows 42 ft apart, each rotor flowing 4.7 GPM.
- Area per head: 34 × 42 = 1,428 sq ft.
- 96.3 × 4.7 = 452.61.
- 452.61 ÷ 1,428 = 0.3170.
PR = 0.32 in/hr. With 96.25: 452.375 ÷ 1,428 = 0.3168, also 0.32 in/hr.
Two slips give the wrong area here. Squaring the spacing along the row (34 × 34 = 1,156 sq ft) gives 0.39 in/hr, and squaring the row spacing (42 × 42 = 1,764 sq ft) gives 0.26 in/hr. The area per head is the two different spacings multiplied together.
How is a whole zone worked at once?
Equation 11-16 is written for a grid of alike heads. A zone with part-circle heads along its edges can be worked on its totals instead: the zone’s whole flow over the zone’s whole area. The Part 652 field worksheet works a sprinkler lateral’s gross application the same way, from the lateral’s total flow over its length times its spacing (Exhibit 9-6, p. 9-125). 30 TAC 344.1(46) defines zone flow for design purposes as “the total flow of all nozzles in the zone at a specific pressure”, which is the figure this needs.
A lawn 44 ft by 28 ft, watered by one zone whose nozzles total 7.8 GPM.
- Area: 44 × 28 = 1,232 sq ft.
- 96.3 × 7.8 = 751.14.
- 751.14 ÷ 1,232 = 0.6097.
PR = 0.61 in/hr. With 96.25: 750.75 ÷ 1,232 = 0.6094, also 0.61 in/hr. Calculation items of this kind are in the Design practice questions.
How does PR turn into run time?
Part 652 pairs the rate with depth = I × H, where I is the precipitation rate and H the set time in hours (p. 9-40). Turned round, the time is the depth divided by the rate.
To put 0.75 in on the 44 by 28 ft lawn:
- 0.75 ÷ 0.6097 = 1.230 hr.
- 1.230 × 60 = 73.8 min.
Run time = 74 min. Worked with 96.25 (rate 0.6094) it is 73.8 min, and with the rate rounded to 0.61 first it is 73.8 min. All three round to 74.
Rounding the rate first can move the minutes when the rate is low. To put 0.5 in on the rotor layout above, 0.5 ÷ 0.3170 × 60 = 94.6 min, which is 95 min, and 96.25 also gives 95. Rounding the rate to 0.32 before dividing gives 0.5 ÷ 0.32 × 60 = 93.8, which is 94. Carrying the unrounded rate through to the last step keeps the answer the same whichever constant is used.
Why must a zone have one rate?
30 TAC 344.62(f) says: “Zones must be designed and installed so that all of the emission devices in that zone irrigate at the same precipitation rate.” The definitions in 344.1 build on it: an irrigation zone is a “subdivision of an irrigation system with a matched precipitation rate”, and a matched precipitation rate is the “condition in which all sprinkler heads within an irrigation zone apply water at the same rate”.
Put the 17 ft spray heads (1.30 in/hr) and the 34 by 42 ft rotors (0.32 in/hr) on one valve, and for every minute it runs the spray area gets 1.2996 ÷ 0.3170 = 4.1 times the depth the rotor area gets. A run time long enough for the rotor area overwaters the spray area by the same factor.
The spacing that goes into the formula is the layout’s own, and 344.62(b)(1) has kept it within plus or minus 10 percent of the maker’s published radius or spacing since July 26, 2020. The rates also go to the owner: the maintenance checklist that 344.1(29) defines, a document made available to the owner, includes “the precipitation rates of each irrigation zone within the system”.
What about triangular spacing?
Neither NRCS equation above is written for heads set on triangles, and this site has found no public source that works that case. Rain Bird’s Landscape Irrigation Design Manual works it on its printed pages 45 and 46. That manual is a maker’s publication, so this page points to it rather than repeating its method.